General Settings > Check Now does not find that newer version is available on systems with a comma as a decimal separator (e.g. German)
Versions / Builds Affected
20130704, 20130723, 20131111
Status
Resolved
Problem Summary
General Settings > Check Now does not find that newer version is available on systems with a comma as a decimal separator (e.g. German)
TT / JIRAID
1721
How to Identify
Let's consider the following scenario: - Installed is version 9.1 (build 20130723) - The latest available version is 9.2 (build 20131111) - You click on the button Configuration > General Settings > Check Now - The check does indicate that no newer version is available - Opening the control file on our servers shows that it actually is (http://update.gfi.com/mar/index.txt) This is happening if the operating system's locale settings are set to a comma as the decimal separator (e.g. on a German system) rather than a fullstop. Note that it is important that index.txt file on our servers can be opened by MARC. If the connection is blocked the check won't work properly either.
Workaround / Fix Details
Fixed in MARC2014 build 20140616 ----- WORKAROUND Check manually on gfi.com
Required Actions
Upgrade to MARC2014 build 20140616 or newer
Priyanka Bhotika