Start a conversation

Connecting to Kerio Hardware Appliances Through a Serial Console

Overview

Connecting to the Kerio Control hardware appliances through a serial console can help you in the following cases:

  • Broken network access to the hardware appliance due to configuration mistakes or network hardware issues (both from the box and network switch sides).
  • Direct access to the Linux shell.
  • You need to see the boot sequence from the hardware appliance.
  • Access to BIOS.

This article provides detailed information on the connection settings used in Kerio hardware appliances via a serial console.

 

Information

Setting a Communication Through a Serial Console

The connection uses these settings:

  • Speed: 9600
  • Data bits: 8
  • Stop bit: 1
  • Parity: None
  • Flow control: None

Accessing BIOS

The connection uses these settings:

  • Speed: 115200
  • Data bits: 8
  • Stop bit: 1
  • Parity: None
  • Flow control: None

 

Related Article

Modifying Kerio Control Configuration via Serial Console

Choose files or drag and drop files
Was this article helpful?