Error: 'System.Servicemodel.Faultexception: There Is Already an Object Named 'Users' in the Database' When Trying to Connect GFI WebMonitor 2012 to an Already Existing Database

Overview

When trying to connect GFI WebMonitor 2012 to an already existing database, the following error is displayed:

System.ServiceModel.FaultException: There is already an object named 'Users' in the database.  Server stack trace:  at System.ServiceModel.Channels.ServiceChannel.HandleReply(ProxyOperationRuntime operation, ProxyRpc& rpc)  at System.ServiceModel.Channels.ServiceChannel.Call(String action, Boolean oneway, ProxyOperationRuntime operation, Object[] ins, Object[] outs, TimeSpan timeout).

 

Information

Environment

  • GFI WebMonitor 2012 
  • All supported environments

Root Cause

The Microsoft SQL database used for reporting in older versions of GFI WebMonitor is incompatible with the GFI WebMonitor 2012 database schema and must be converted.

 

Process

  1. Under the Settings > General > Database page, enter the name of a database that does not exist on the Microsoft SQL Server and make sure to save the changes. This will create a new GFI WebMonitor 2012 database.
  2. Afterward, you will have the option to run the \GFI\WebMonitor\WebMonDataImporterTool executable to transfer the data from a WebMonitor 2011 firebird database (or 2009 SQLite databases) into the new WebMonitor 2012 database.

    305.png
Choose files or drag and drop files
Was this article helpful?